Bentley SewerGEMS CONNECT Edition Help

Annotating

In order to annotate the elements in the drawing, the SCADA data must be imported to User Data Extension (UDX). To import the SCADA data into a UDX field follow the steps provided in Load Extended Data.

Steps for Annotation:

  1. Load data to User Data Extension or go to Load Extended Data.
  2. Go to View > Element Symbology.
  3. Right click on the desired element and select New > Annotation. (Desired element must have at least one signal mapped.
  4. Annotation Properties opens.
  5. Click on > button, next to the Field Name drop down and select SCADA Data.
  6. Provide X Offset, Y Offset, and Height Multiplier values.
  7. Click Apply and OK.